- House Wires
AWM – APPLIANCE WIRING MATERIAL | 600V, 105°C
- Specification: - Testing Standards - UL 758 & UL 1581 - Conductor - 19 wire combination of round uni-lay or semi-lay stranded conductor - has flexibility with less diameter. - Insulation - Thermoplastic PVC insulation is suitable uptil 105 ºC. - Comply to Vertical Flame test and Horizontal Flame test - of VW-1. - Colors & packing options are available…
- Read more
-
- House Wires
CU/PVC | 450/750V
- Specification: - Testing Standards - BS EN 50525-2-31 & 60227 IEC 01 and SASO 1320. - Flame Retardant - Vertical Flame Propagation - IEC 60332-1 - Test Conductor - Soft annealed copper as per BS EN 60228, Class 1, Class 2 stranded and Class 5 flexible conductor. - Insulation - Thermoplastic insulation type PVC/E as per IEC 60227 90°C &…
- Read more
-
- House Wires
CU/PVC | 600/1000V
- Specification: - Testing for Type 6231. Also Vertical Flame Propagation retardant as per IEC 60332-1 - Conductor - Soft annealed copper as per BS EN 60228, Class 5 flexible conductor. - Insulation - Thermoplastic insulation - PVC type TI 1 70 °C as per BS EN 50363-3 and type PVC TI 3 90 °C as per BS EN 50363-3 -…
- Read more
-
- House Wires
Flat Cables | 300/500V
- Specifications: - As per IEC and BS standards - Flame Retardant to IEC 60332-1 with Vertical Flame Propagation Test. - Conductor - Soft annealed copper as per BS EN 60228, Class 1, Class 2 stranded and Class 5 for flexible conductor. - Insulation - Thermoplastic - PVC shall be type PVC TI 1 70°C and type PVC TI 3 90…
- Read more
-
- House Wires
Flexible Cables | 300/500V
- Specification: - Testing type 60227 IEC 53, BS EN 50525-2-11 & SASO 1321 - Flame Retardant to IEC 60332-1 with Vertical Flame Propagation Test. - Conductor - Annealed flexible copper - as per BS EN 60228 of class 5 - Insulation - Thermoplastic insulation - PVC type PVC TI 1 70 °C as per BS EN 50363-3 and type PVC…
- Read more
-
- House Wires
THHN / THWN | 600V
- Specification: - Testing standards - UL 83 & UL 1581 - Conductor - 19 wire combination of round unilay stranded conductor - has flexibility with smaller diameter - Insulation - Thermoplastic PVC insulation suitable - 105 & 90 ºC dry and 75 ºC for wet location. - According to vertical flame tests - VW-1. - Jacketing - Polyamide Nylon over…
- Read more
-
- House Wires
XHHW / XHHW-2 | 600V
- Specifications: - Tested according to - UL 44 & UL 1581 - Conductor - 19 wire combination of round unilay stranded conductor - has flexibility with less diameter. - Insulation - thermoseting XLPE insulation suitable - 90 ºC dry and 75 ºC wet location. - Wires have chemical resistance and comply to flame and smoke requirment of UL 44 FT2/FH/Horizontal…
- Read more